6.3.4 Wire Lengths and Shielding
The following maximum lengths for wires and the type of shielding to be used must be
observed:
Table 6.2: Wire Lengths and Shielding
6.4 Disassembling, Packing, Disposing
Repacking
For later re-use, the device is to be packed so that it is protected against shocks and damp-
ness. Optimal protection is achieved when using the original packaging.
Notice!
Electrical scrap is a special waste product! Observe the locally applicable regulations re-
garding disposal of the product.
Connecting Interface Max. wire length Shielding
BPS 37 - Service RS 232 10m
absolutely required, shield
meshing
BPS 37/MA 4.7 -
Host
SSI 1200m
absolutely required, flexible
leads as twisted pairs and
shielded
Switching input 10m not necessary
Switching output 10m not necessary