Przeglądanie stron 12
Leuze electronic Technical Data
Leuze electronic BPS 37 11
TNT 35/7-24V
4 Technical Data
4.1 General Specifications BPS 37
Optical Data
Light source Laser diode 650nm
Scanning rate 1000scans/sec.
Measurement data
Reproducible accuracy ±1 (2) mm
Integration time 16 (8) ms
Measurement value output
Refresh time
500 values/sec.
Scanning depth 90 … 170 mm
Electrical data
Interface type
(standard setting)
SSI (RS422)
electrically isolated
bits 0 … 24: data bits with position value
bit 25: error bit
resolution: 1mm
800 kHz max. clock frequency
output of positive and negative position values
gray coded
Service interface RS232 with fixed data format,
9600Bd, 8 data bits, no parity, 1 stop bit
Ports 1 switching output, 1 switching input
LED green device ready (Power On)
Operating voltage 10 … 30V
Power consumption 3.2 W
Mechanical data
Protection class IP 65
Weight 400 g
Dimensions (W x H x D) 120 x 90 x 43mm
Housing diecast aluminium
Environmental data
Operation w/o optics heating
Operation with optics heating
Storage
0°C … +40°C (BPS 37 S M 100)
-3C +4C (BPS 37 S M 100 H)
-2C +6C
Air humidity max. 90% rel. humidity, non-condensing
Vibration IEC 68.2.6
IEC 68.2.27 (shock)
IEC 801
Electromagnetic compatibility acc. to IEC 60947-5-2